型號 |
TL2300 EPA |
TL2310 ISO |
TL2350 EPA |
TL2360 ISO |
測量方法 |
濁度計 |
符合法規 |
EPA 180.1 |
ISO7027
DIN EN 27027
DIN 38404 和 NFT 9033 |
EPA 180.1 |
ISO7027
DIN EN 27027
DIN 38404 和 NFT 9033 |
檢測光源 |
鎢燈 |
LED 860±30nm |
鎢燈 |
LED 860±30nm |
顯示單位 |
NTU
RatioON:0-4000
RatioOFF:0-40
EBC
RatioON:0-980
RatioOFF:0-9.8 |
FNU、NTU:0-1000 |
NTU(Ratio on):
0-10000自動小數點
NTU(Ratio off):0-40
EBC(Ratio on):
0-2450自動小數點
EBC(Ratio off):0-9.8
吸光度:0-1.0
透光率:1.0-100%
度:1-100mg/L |
FNU(Ratio on):0-1000
FNU(Ratio off):0-40
FAU:20-10000自動量程
NTU(Ratio on):
0-10000自動小數點
NTU(Ratio off):0-40
EBC(Ratio on):
0-2450自動小數點
EBC(Ratio off):0-9.8
吸光度:0-2.0
透光率:1.0-100%
度:0-100mg/L |
測量精度 |
RatioON
0-1000NTU:±2%讀數+0.01NTU
1000-4000NTU:±5%
RatioOFF
0-40NTU:±2%讀數+0.01NTU |
0-1000NTU/FNU:±2%讀數+0.01NTU |
RatioON
0-1000NTU:±2%讀數+0.01NTU
1000-4000NTU:±5%
4000-10000NTU:±10%
RatioOFF
0-40NTU:±2%讀數+0.01NTU |
FNU:0-1000FNU:±2%讀數+0.01FNU
20-10000FAU:±2%讀數+0.01FAU
NTU
0-1000NTU:±2%讀數+0.01NTU
1000-4000NTU:±5%
4000-10000NTU:±10% |
吸光度 |
|
|
吸光度
±0.005Abs@0-1Abs 860nm
透光率
0.12%T@10-100%T 860nm |
分辨率 |
0.001NTU/EBC |
濁度:0.001NTU/EBC
吸光度: 0.001Abs
透光率: 0.1% T |
重復性 |
±1%讀數 或0.01NTU,最大值(參考條件下) |
響應時間 |
信號平均關閉:6.8秒
信號平均開啟:14秒 |
穩定時間 |
RatioON:30分鐘
RationOFF:60分鐘 |
開機即可測試 |
RatioON:30分鐘
RationOFF:60分鐘 |
開機即可測試 |
讀數模式 |
單次,連續,RST,信號平均,Ratio |
單次,連續,RST,信號平均 |
單次,連續,RST,信號平均,Ratio |
手動或自動量程,信號平均,Ratio |
通訊接口 |
USB |
通訊界面 |
2個USB-A用于閃存,外部打印機,鍵盤和條形碼掃描儀 |
數據記錄 |
2000條數據,包括讀數記錄,驗證記錄和校準記錄 |
空氣吹掃 |
干燥氮氣或儀器級空氣(ANSI MC 11.1,1975)
0.1 scfm @ 69kPa(10 psig);138kPa(20PSIG)最大
連接氣管1/8'
|
樣品池兼容 |
圓形樣品池95x25mm(3.74x1 in.)硼硅玻璃帶蓋
注:使用適配器時可使用最小樣品池(不小于25mm) |
樣品要求 |
25mm樣品池:20ml最小
0-70℃(32-158℉) |
認證證書 |
CE,KC,RCM |
供電要求 |
100-240VAC,50/60Hz,3.4A |